Specification
Order No. | 389-261-30 |
---|---|
Range (mm) | 0 - 25 |
Resolution (mm) | 0.001 |
Maximum permissible error JMPE (µm) | ±4 |
Flatness (µm) | 0.6 |
Parallelism (µm) | 3 |
Throat depth (mm) | 150 |
Measuring surfaces | S-F |
Digital/Analog: | Digital |
Inch-Metric: | Metric |
• Battery: SR44 (1 pc.), 938882, 2 pcs.: 389-514, 389-714 for initial operational checks (standard accessory)
• Battery life: Approx. 2.4 years under normal use (for 389-2XX, 3XX), Approx. 1.8 years under normal use (for 389-514, 714)
• Length standard: Electromagnetic rotary sensor
• Standard accessories: Setting standard, 1 pc. (except for measuring range 0 to 25 mm (0 to 1 in) models)
Spanner (301336), 1 pc. (for 389-2XX, 3XX)
Spanner (200154), 1 pc. (for 389-514, 714)
* Models with a 300 mm (12 in) throat are equipped with a stand for convenience of measurement in the horizontal orientation as standard.