Order No. | 518-246 |
---|---|
Measuring range (stroke) | 0 to 715 mm (600 mm/ 24 in) |
Resolution : Metric | 0.001 mm/ 0.005 mm (Selectable) |
Resolution : Inch /Metric | 0.001/ 0.005 mm 0.00005 /0.0001/0.0002 in (Selectable) |
Accuracy at 20 ˚C : Indication accuracy*1 | ± (2.4 + 2.1L / 600) µm |
Accuracy at 20 ˚C : Repeatability*1 | 2 σ ≤ 1.8 µm |
Perpendicularity*2 (20 ˚C) | 12 µm |
Guiding method | Roller bearing |
Drive method | Manual (wheel) |
Measurement principle | Electromagnetic induction absolute encoder |
Measuring force | 1.5±0.5 N |
Data output ports | Digimatic / USB*3 |
Air-floating system | Included (for positioning only)*4 |
Power supply | Alkaline AA / LR6 batteries×4 (standard accessories) /AC adapter (optional accessory)*5 / Supports NiMH (HR6) rechargeable batteries×4 |
Battery life guidelines*6 | Approx. 1,200 hours (without using the air-floating system) |
Approx. 90 hours (when using the air-floating system) | |
Mass | 30 kg |
Dimensions (W×D×H) | Stroke 350 mm type: 280×273×784 mm Stroke 600 mm type: 280×273×1016 mm |
Operating temperature range (recommended) | 0 to 40 ˚C (10 to 30 ˚C) |
Operating humidity range | 20 to 80% RH (non-condensing) |
Storage temperature range | -10 to 50 ˚C |
Storage humidity range | to 90% RH (non-condensing) |
• Standard Accessories: 05HZA148 ø5 mm stepped probe, 12AAA715 Probe diameter calibration block, Alkaline batteries×4 (AA/LR6)
*1 The indication accuracy and repeatability represent the values obtained from the height measurement of a flat surface using the standard holder with ø5 ball contact point. In the case of diameter, minimum (maximum) value, circle pitch or difference measurement, measuring errors may be larger than the accuracy ratings listed in the table due to variations in measuring force during a scanning measurement, which differs from height measurement.
*2 Indicates the value obtained from the measurement of a straight surface placed perpendicular to the the base reference surface using the Lever Head (519-521) and Mu-checker (519-551).
*3 Requires special communication driver. Consult your local Mitutoyo Sales Office for details. These can be downloaded from the Mitutoyo web site. https://www.mitutoyo.co.jp/eng/contact/products/usb/index.html
*4 When using a model with the air-floating system, it is advisable to use a JIS 1 class, or higher, surface plate. Using on surfaces with scratches or unevenness may prevent the system operating to the specified performance.
*5 The AC adapter cannot be used to recharge rechargeable batteries.
*6 Battery life depends on the operating conditions. In particular, it is more economical to use the optional AC adapter to power the instrument if the application requires prolonged use of the air-floating system.