511-817-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 400-600mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-817-20
Range: 400-600 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-816-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 250-400mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-816-20
Range: 250-400 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-815-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 150-250mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-815-20
Range: 150-250 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-814-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 100-160mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-814-20
Range: 100-160 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-813-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 60-100mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-813-20
Range: 60-100 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-828-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 600-800mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-828-20
Range: 600-800 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-827-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 400-600mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-827-20
Range: 400-600 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-826-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 250-400mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-826-20
Range: 250-400 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-825-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 150-250mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-825-20
Range: 150-250 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-824-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 100-160mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-824-20
Range: 100-160 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-823-20 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 60-100mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-823-20
Range: 60-100 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.
511-808 | BORE GAGE SERIES 511 – WITH MICROMETER HEAD, 600-800mm | MITUTOYO
BORE GAGE SERIES 511 – WITH MICROMETER HEAD
Order No.: 511-808
Range: 600-800 mm
Description:
• The micrometer head is used for dimensional setting. The dimension can be easily changed without replacing the anvil and washer.
• The contact point has a carbide ball tip that is highly durable and abrasion-resistant.
• The grip minimizes the variation of indicator values affected by heat transfer from the operator’s hand.