- Sort by Popularity
- Display 12 Products per page
-
568-474 | ABSOLUTE BOREMATIC SERIES 568 – ABSOLUTE DIGIMATIC SNAP-OPEN BORE GAGES 4-4.5″ | MITUTOYO
ABSOLUTE BOREMATIC SERIES 568
ABSOLUTE DIGIMATIC SNAP-OPEN BORE GAGES
Range : 4-4.5″
Order No. : 568-474
Description :
This is a individual unit Three-Point Digimatic Snap Open Bore Gauge.
It offers you the following benefits:- It enables you to take measurements easily and quickly.
- Titanium-coated measuring pins gives you excellent durability and impact resistance.
- 330° rotatable display unit also gives you easy reading at any angle.
- GO/NG tolerance judgement function.
-
137-206 | TUBULAR INSIDE MICROMETERS SERIES 137 – EXTENSION ROD TYPE, 50-150mm | MITUTOYO
TUBULAR INSIDE MICROMETERS SERIES 137 – EXTENSION ROD TYPE
Order No.: 137-206
Range : 50-150mm
Description :
• Wide range of inside measurements possible by combining Extension Rods and anvils with the micrometer head.
• Two types of measuring faces are available; with or without carbide tip. (The 337 Series is only available with carbide tip)
• The sleeve is rotated to adjust the reference point adjustment when setting to a length standard.
• An inside length standard is required for accurately setting the micrometer. -
526-173-20 | BORE GAGES SERIES 526 – FOR EXTRA SMALL HOLES, 0.95 – 1.55mm | MITUTOYO
BORE GAGES SERIES 526 – FOR EXTRA SMALL HOLES
บอร์เกจ – สำาหรับรูขนาดเล็กมาก
Order No.: 526-173-20
Range: 0.95 – 1.55 mm
Description:
• This series allows for agile and highly accurate comparative measurement of ø1 to 7 mm inside diameters.
• We offer an array of indicators. Contact us if you prefer any indicator other than the standard recommended indicator.
• Optional stand (215-120-10) is available for efficient measurement of multiple small holes. -
468-274 | Digimatic Holtest – 3-point Internal Micrometers – Series 468 | MITUTOYO
DIGIMATIC HOLTEST – 3-POINT INTERNAL MICORMETER | MITUTOYO
Order No. : 468-274
Range : 4-5″
Description :
• Three-point internal micrometer with large LCD readout. (Character height 7.4 mm)
• Deep holes can be measured by attaching an Extension Rod (optional).
• Measurements can be made close to the bottom of a blind hole.
• Titanium-coated measuring pins provide excellent durability and impact resistance.
• Two preset values can be stored as reference points. -
368-161 | Holtest – Three-Point Internal Micrometer Holtest 6-8mm | MITUTOYO
3-POINT INTERNAL MICROMETER HOLTEST | MITUTOYO
Order No. 368-161
Range. 6-8 mm
Description
• Titanium-coated measuring pins on the three-point type (over 6 mm range models) provide excellent durability and impact resistance.
• Three-point internal micrometer with measuring range 6 mm or longer allows stable measurement through self-centering.
• Measurement can be made close to the bottom of a blind hole.
• Deep holes can be measured by attaching an Extension Rod (optional) which is available on models over 6 mm (0.275 in) measuring range. -
133-172 | TUBULAR INSIDE MICROMETERS SERIES 133 – SINGLE ROD TYPE, 775-800 mm | MITUTOYO
TUBULAR INSIDE MICROMETERS SERIES 133 – SINGLE ROD TYPE
Order No. : 133-172
Range : 775-800mm
Description :
• Standard Single-Rod Type inside micrometer.
• Carbide measuring faces.
• The sleeve is rotated to adjust the reference point adjustment when setting to a length standard.
• Optional Setting Rings (nominal size below 300 mm), CERA Inside Micro Checker and Gauge Block Accessory Sets are available as reference gages datum adjustment. -
145-192 | INSIDE MICROMETER SERIES 145 – CALIPER TYPE, 175-200mm | MITUTOYO
INSIDE MICROMETER SERIES 145 – CALIPER TYPE
Order No. 145-192
Range: 175-200mm
Description:
• Carbide measuring faces.
• Equipped with a constant measuring-force device.
• Optional Setting Rings (nominal size below 300 mm), CERA Inside Micro Checker (more than 25 mm) and Gauge Block Accessory Sets are available as reference gages for datum adjustment. -
141-001 | INSIDE MICROMETERS SERIES 141 – INTERCHANGEABLE ROD TYPE, 25-32mm | MITUTOYO
INSIDE MICROMETERS SERIES 141 – INTERCHANGEABLE ROD TYPE
Order No. 141-001
Range: 25-32mm
Description:
• Wide range of inside measurements possible by combining one or more Interchangeable Rods.
• For models supplied with more than one Interchangeable Rod, the full measuring range is achieved by combining spacing collars with the rods. -
468-974 | Digimatic Holtest – 3-point Internal Micrometers Set (Interchange-Head Set) – Series 468 | MITUTOYO
DIGIMATIC HOLTEST – 3-POINT INTERNAL MICORMETER SET | MITUTOYO
Interchange-Head Set
Order No. : 468-974
Range : 50-100 mm
Description :
• Three-point internal micrometer with large LCD readout. (Character height 7.4 mm)
• Deep holes can be measured by attaching an Extension Rod (optional).
• Measurements can be made close to the bottom of a blind hole.
• Titanium-coated measuring pins provide excellent durability and impact resistance.
• Two preset values can be stored as reference points. -
368-172 | Holtest – Three-Point Internal Micrometer Holtest 75-88mm | MITUTOYO
3-POINT INTERNAL MICROMETER HOLTEST | MITUTOYO
Order No. 368-172
Range. 75-88 mm
Description
• Titanium-coated measuring pins on the three-point type (over 6 mm range models) provide excellent durability and impact resistance.
• Three-point internal micrometer with measuring range 6 mm or longer allows stable measurement through self-centering.
• Measurement can be made close to the bottom of a blind hole.
• Deep holes can be measured by attaching an Extension Rod (optional) which is available on models over 6 mm (0.275 in) measuring range. -
337-301 | TUBULAR INSIDE MICROMETERS SERIES 337 – EXTENSION ROD TYPE, 200-1000 mm | MITUTOYO
TUBULAR INSIDE MICROMETERS SERIES 337 – EXTENSION ROD TYPE
Order No. : 337-301
Range : 200-1000mm
Description :
• Wide range of inside measurements possible by combining Extension Rods and anvils with the micrometer head.
• Two types of measuring faces are available; with or without carbide tip. (The 337 Series is only available with carbide tip)
• The sleeve is rotated to adjust the reference point adjustment when setting to a length standard.
• An inside length standard is required for accurately setting the micrometer.